- Intuitive measurement menus and fast-response Smart-Touch display
- Including O2 and CO sensor up to 4,000 ppm
- 3rd sensor slot to allow optional Nitric Oxide (NO) sensor to be fitted to allow device to give calculated NOx measurement (sensor 0393 0151 required)
- Integrated micro-pressure measurement
- Documentation on site and reports sent by e-mail
- Versatile probes and fast probe changes by the user
Handset only upgrade to allow existing testo FGA owners to convert over to the innovative testo 300 touchscreen FGA : the testo 300 flue gas analyzer is supplied with O2 sensor, and CO sensor up to 4,000 ppm – This is handset only and will require existing users sampling probe, case, etc.
Truly smart flue gas measurement on heating systems with the testo 300 flue gas analyzer. High-quality sensors, intuitive operation with smart-touch technology and smart features, such as efficient documentation and e-mailing of reports, will make your day-to-day work easier.
testo 300 flue gas analyzer with smart-touch operation – Features
Impressive measuring technology and quality
• Fitted with O2 sensor, and 4,000ppm CO sensor
• Longer sensor service life thanks to automatic sensor protection
• TÜV-tested according to EN 50379, Parts 1-3
• Supplied with compact flue gas probe with latching connector to ensure a reliable and robust connection
• Optionally available probes and accessories for further measuring tasks, such as gas flow pressure measurement, gas pipe testing, differential temperature measurement and ambient CO measurement.
Smart, intuitive, efficient: easy operation in day-to-day work
• Smart-touch display for intuitive operation of the flue gas analyser: the display responds without delay – just as easy as on your smartphone
• Get the measurement result faster: clearly structured measurement menus for all relevant measurements
• Create documentation (including measuring value, measuring location, customer data) easily on site
• Save PDF measurement reports directly in the instrument and always have them available
• Signature function: your customer can sign measurement reports directly on the instrument
• E-mail measurement reports directly to the office or to customers via WiFi hotspot
• Large 5-inch HD display – enables you to see all the system’s parameters immediately
• Ready to use straight away: in standby mode, the testo 300 is ready to measure at the touch of a button. Use it straight away with the next customer – because you no longer need to wait for the end of the zeroing phase
• Integrated Bluetooth® interface: immediate printout of the measuring values on site with the appropriate printer (optional) or transfer of pdf reports to PC or smartphone.
Applications
Flue gas measurement on heating systems
Ideal for measurements involving heating systems:
- high-quality sensors, smart-touch operation, clearly structured measurement menus, creation of documentation on site, e-mailing of reports, large HD display, robust housing
Further areas of application:
- gas flow pressure measurement*, gas pipe test*, differential temperature measurement (flow and return temperature on heating systems)*, ambient CO measurement*, flue draught measurement on heating systems*
* Please note: additional probes or accessories are required for these measurements and have to be ordered separately.
Click below to Download Testo 300 Data Sheet
General technical data |
Operating humidity |
15 to 90 %RH non-condensing |
Weight |
approximately 800 g |
Dimensions |
244 (including probe connection) x 98 x 59 mm (LxWxH) |
Operating temperature |
-5 to +45 °C |
Protection class |
IP40 |
Product colour |
black/orange |
Display type |
5.0″ touch display, HD 1280*720 pixels, IPS (160 k) |
Power supply |
Rechargeable battery, USB mains unit |
Authorizations |
TÜV-tested according to 1st German Federal Immission Control Ordinance (BImSchV) EN 50379, Parts 1-3 |
Guarantee |
Gas sensors (O₂, CO) 24 months; rechargeable battery: 12 months; Thermocouple 12 months |
Memory |
1,000,000 measuring values |
Storage battery type |
Lithium ion battery |
Battery life |
10 h |
Storage temperature |
-20 to +50 °C |
Charging temperature |
0 to +45 °C |
Temperature – TC Type K (NiCr-Ni) |
Measuring range |
-40 to +1200 °C |
Accuracy |
±0.5 °C (0.0 to +100.0 °C)
±0.5 % of mv (Remaining Range) |
Resolution |
0.1 °C (-40 to +999.9 °C)
1 °C (Remaining Range) |
Differential Pressure – Piezoresistive |
Measuring range |
-100 to +200 hPa |
Accuracy |
±0.5 hPa (0 to +50.0 hPa)
±1 % of mv (+50.1 to +100.0 hPa)
±1.5 % of mv (+100.1 to +200 hPa) |
Resolution |
0.01 hPa |
Flue gas O₂ |
Measuring range |
0 to 21 Vol.% |
Accuracy |
±0.2 Vol.% |
Resolution |
0.1 Vol.% |
Differential Pressure flue gas Draught – Piezoresistive |
Measuring range |
-9.99 to +40 hPa |
Accuracy |
±0.005 hPa (+0 to +0.1 hPa)
±0.02 hPa (+0.1 to +3.00 hPa)
±1.5 % of mv (3.01 to +40 hPa) |
Resolution |
0.001 hPa (0 to 0.1 hPa)
0.01 hPa (Remaining Range) |
Flue gas degree of effectivity, Eta (calculated) |
Measuring range |
0 to 120 % |
Resolution |
0.1 % |
Flue gas loss (calculated) |
Measuring range |
0 to 99.9 % |
Resolution |
0.1 % |
Flue gas CO₂ calculation (calculated from O₂) |
Measuring range |
Display range 0 to CO₂ max |
Accuracy |
±0.2 Vol.% |
Resolution |
0.1 Vol.% |
Flue gas CO (without H₂-compensation) |
Measuring range |
0 to 4000 ppm |
Accuracy |
±20 ppm (0 to 400 ppm)
±5 % of mv (401 to 2000 ppm)
±10 % of mv (2001 to 4000 ppm) |
Resolution |
1 ppm |
Measuring range |
0 to 2000 ppm |
Accuracy |
±10 ppm (0 to 100 ppm)
±10 % of mv (101 to 2000 ppm) |
Resolution |
1 ppm |
Differential Pressure 4 Pa measurement – Piezoresistive |
Measuring Range |
-50 to +50 Pa |
Accuracy |
±0.3 Pa (< 10 Pa)
±3 % of mv (Remaining Range) |
Resolution |
0.1 Pa |