1. This product was added to our catalog on Thursday 10 January, 2013.

    Testo 570-1 - Refrigeration Manifold Kit
    [0563 5701]

    Price:  £559.00

    Reviews


  2. Testo 570 - Digital Refrigeration Manifold

    4-way-valve block, internal data memory, integrated vacuum measurement, 3 temperature probe connections, 40 refrigerants stored

    • Includes pliers temperature probe

    • batteries

    • instruction manual and calibration protocol.

    • 4-way valve block with 4 connections, 4 hose parkers and sight glass

    • Integrated vacuum measurement supports evacuation of the system

    • Heat pump mode and display of high and low pressure as well as temperature

    • Temperature-compensated tightness testing

    • Additional calculation of superheating and subcooling

    • Computer-supported monitoring of a system with up to 999h of measurement value recording

    • 40 refrigerants stored

    • “EasyKool” software with extended features

    • Refrigerant management and administration of exact filling levels


    Your toolcase is probably heavy, and filled with many useful helpers for your daily work. In the future, the new testo 570 will replace several of these tools. Because it is the robust expert for all imaginable measurements on a refrigeration system or heat pump with one instrument. Whether for pressure, temperature or current, you benefit from the extensive analysis possibilities and numerous technical features for all measurement tasks on a system. The testo 570-1 set contains one clamp probe, a calibration protocol and batteries.

    The digital manifold testo 570 offers you all you need for your work on refrigeration systems and heat pumps. The internal data store of the testo 570 replaces manual work steps, thanks to the clear and easily understood documentation option of a measurement. Carry out long-term measurements or record data in real time, and present them graphically. The easy operation of testo 570 makes this possible. Apart from this, errors can be found and rectified more quickly in cases of malfunction. Manual documentation is a thing of the past. Measurement results can be traced, and reports called up, at any time.

    Technical Data
    Storage temperature -20 to +60 °C
    Operating temperature -20 to +50 °C
    Battery life40 h (wthout illumination)
    Weightapprox. 1200g (without batteries)
    Dimensions 280 x 135 x 75 mm
    Pressure mediaHCFC, CFC, N, CO2, H2O
    Probe Connections 3 x plug-in (NTC)
    Meas. range -50 to +150 °C
    Accuracy (at 22 °C) ±0.5°C (± 1 digit)
    Resolution 0.1 °C / 0.1 °F
    Meas. range (rel.)
    Meas. Range 1 bar to 0 bar
    Accuracy (at 22 °C) 1 % fs
    Resolution1mbar/ 1hPa/ 0.5Torr/ 0.5.5inH2O/ 100Pa/ 500Micron
    Low Pressure 50/50 bar (rel)
    Accuracy (at 22 °C) 0.5% fs (±1 digit)
    Resolution 0.01 bar / 0.1 psi
    Overload LP/HP: 52 bar
    Connections3 x 7/16“ UNF + 1 x 5/8“ UNF
    Printer IR printer
    Data store in instrument Record up to 999 h measurement values
    Optional software EasyKool
    Refrigerants in instrumentR12, R22, R123, R134a, R227, R290, R401A, R401B, R402A, R402B, R404A,R406A, R407A, R407C, R408A, R409A,R410A, R411A, R413A,R414B, R416A,R417A, R420A, R421A, R421B, R422A,R422B, R422D, R424A, R427A, R434A,R437A, R438A, R502, R503, R507,R600, R600a, R718 (H2O), R744 (only in the permitted range up to 40 bar), R1234yf
Manufacturers